Flow measurement technology since 1951
You are here BAMO KIRCHNER English » Products » Flow meters » Variable Area » RA 65 / FA 65
Product 727-03
RA 65 / FA 65
RA 65 / FA 65
Variable area flowmeters
RA 65 / FA 65


Left : Output contacts
Right : 4-20 mA output with Hall-effect sensor

1) MSK limit switch
2) M12 angular connector
3) Variable area flow meters (or rotameters)
4) Measuring tube
5) Magnetic float (specific term for the float used in a variable area flow meter)

PRINCIPLE
  • For liquids and gases
  • Direct reading on the glass tube
  • Measuring range: 0.5 l/h to 16 m³/h (water)
  • Materials: glass, steel, or stainless steel
  • Options: ATEX versions, switches, 4–20 mA output
APPLICATIONS

Direct measurement and visualisation of instantaneous flow rate of gases and liquids:

Water treatment, industrial processes (paper, textiles, etc.), chemical and pharmaceutical industries, heating or cooling circuits

DESCRIPTION

The measuring principle is that of a variable area flowmeter, achieved by a float moving inside a calibrated conical glass tube. The borosilicate glass cone is housed in a protective steel tube with a viewing window.

 

Available versions:

RA 65   threaded connection Rp ¼" to Rp 3"
FA 65   flanged connection DN 10 to DN 65
RA / FA 65-MSK1   with limit switch (normally closed contact)
RA / FA 65-MSK2   with limit switch (normally open contact)
RA / FA 65-MSKW   with changeover contact
RA / FA 65-EM   with 4 ... 20 mA analog output
RA / FA 65... Ex   explosion-proof version

 

Limit switches:

 

These flowmeters can be equipped with a magnetic float and electrical reed contacts, adjustable across the full measuring range.

 

4–20 mA analog output:

 

The output is obtained via a Hall-effect linear displacement sensor. A 4–20 mA signal is generated, representing the position of the float. The sensor is connected via the supplied M12 × 1 connector. The assembly is compact and offers a high level of repeatability. An LED indicator mounted on the strip displays the measuring range.

Product 727-03
08/07/2026 16:43
Variable area flowmeters
RA 65 / FA 65
Your contacts within our company
Online inquiry
A. Kirchner & Tochter GmbH
Dieselstraße 17

D-47228 Duisburg
Telephone: +49 2065 9609-0
Fax: +49 2065 9609-22
E-Mail: info@kt-flow.de
Internet: www.bamo-kirchner.de
Commercial register court: Duisburg
Registration number: HR B 6458

VAT identification number: DE 169756218
Made by CARIMEDIA since 1998
© 1998-2026 - Legal notice